ATLAS ULTRA GEOFLEX C2TE S1 Gel Adhesive extended information
Consumption:
Tiles size [cm] | Place of application | Recommended notches size (mm) | Consumption (kg/m3) |
---|---|---|---|
2 x 2 | wall floor | 4 4 | 1.3 1.3 |
10 x 10 | wall floor | 4 6 | 1.3 2.0 |
15 x 60 | wall floor | 6 8 | 2.0 2.5 |
20 x 25 | wall floor | 6 8 | 2.0 2.5 |
25 x 40 | wall floor | 6 8 | 2.0 2.5 |
30 x 30 | wall floor | 6 8 | 2.0 2.5 |
30 x 60 | wall floor | 8 10 | 2.5 3.0 |
40 x 40 | wall floor | 8 10 | 2.5 3.0 |
50 x 50 | wall floor | 8 10 | 2.5 3.0 |
60 x 60 | wall floor | 10 12 | 3.0 3.5 |
above 60x60 e.g. 90 x 90, 120 x 20, 300 x 100 | wall floor | 10 12 (semi-circular notched trowel) | 3.0 4.6 |
tiles – slab type* e.g. 20 x 90 or 15 x 100 | wall floor | 8 10 | 2.5 3.0 |
GEL TECHNOLOGY
The unique gel technology used in ATLAS GEOFLEX WHITE brings the following advantages:
- adhesive is suitable for any type or size of cladding: especially for extra-large tiles, natural stone,, ceramic, porcelain,
- consistency of adhesive can be adjusted to individual preferences of the tiler and needs of specific job – mixing ratio is much wider than in case of traditional adhesives,
- bed depth up to 15 mm – substrate levelling and tiling at once,
- full spread under the tile with higher mixing ratio – ensured adhesion and durable bond, which is relevant for exterior use,
- safe cladding installation on surfaces exposed to direct sunlight – during fixing cladding, as well as during mortar setting (e.g. on balcony, terrace).
ATLAS ULTRA GEOFLEX Properties
ATLAS ULTRA GEOFLEX is a grey C2TE S1 adhesive for tiles manufactured as a dry mix of high quality cement binder, aggregates and selected modifying agents.
S1 deformability – for deformable substrates and extra-large tiles.
Wide range of bed thickness from 2 up to 15 mm.
No slip from the wall, even for extra-large tiles and stone slabs – cladding can be installed from the top of the wall with no additional support.
Perfect support for extra-large tiles (above 5 m2) applied on a floor – heavy tiles do not sunk into adhesive.
Walking on and grouting just after 12 hours – owing to accelerated process of adhesive setting and drying.
Recommended for tiling in drinking water tanks, food industry, health care facili- ties, nursery houses, kindergartens etc.
Use
Cladding Type
glazed tiles | + |
terracotta | + |
porcelain tiles | + |
laminated tiles | + |
natural stone (granite, marble, travertine, syenite, slate) | application test required* |
clinker | + |
stoneware | + |
ceramic mosaic | + |
glass mosaic | application test required* |
glass, coloured, printed tiles | application test required* check recommendations of tiles manufacturer |
concrete/cement tiles | + |
composite slabs | + |
insulation and sound absorbing panels | + |
Size of Installed Elements
any tile size, even above 5 m2 | + |
slim type tiles | + |
Object Type
residential buildings | + |
public access, educational, office and healthcare facilities | + |
commercial and service buildings | + |
sacral buildings | + |
industrial buildings and multi-storey garages | + |
industrial warehouses | + |
infrastructure buildings | + |
SPA objects | + |
Installation Area
surfaces with low traffic | + |
surfaces with moderate traffic | + |
surfaces with large traffic | + |
kitchen, bathroom, laundry, garage (in residential buildings) | + |
terraces | + |
balcony, loggia | + |
external slab stairs | + |
external post stairs (e.g. cantilever stairs) | + |
communication routes | + |
facades (including external thermal insulation systems) | + |
cladding on a plinths | + |
technological reservoirs, swimming pools, fountains, jacuzzi, balneotechnology (without aggresive chemical agents) | + |
drinking water reservoirs | + |
sauna | + |
showers, car washes, rooms washed with plenty of water | + |
Substrate Type – Standard
cement floors and screeds | + |
anhydrite screeds | + |
cement, cement-lime plasters | + |
gypsum plasters | + |
cellular concrete | + |
silicate brick or hollow blocks | + |
ceramic brick or hollow blocks | + |
gypsum blocks | + |
Substrate Type – Difficult
concrete | + |
terrazzo | + |
mineral, dispersive and reactive sealing coats | + |
plasterboard drywall | + |
screeds (cement or anhydrite) with water or electrical underfloor heating | + |
screeds with heating mat embedded in the adhesive | + |
plasters with wall heating | + |
plasterboards | + |
gypsum fibre boards | + |
cement fibre boards | + |
existing ceramic or stone cladding (tile on tile) | + |
resin varnishes on concrete, bonded with substrate | + |
dispersive, oil painting coats, bonded with substrate | + |
timber floors (thickness > 25 mm) | + |
OSB/3, OSB/4 and plywood boards on the floor (thickness > 25 mm) | + |
OSB/3, OSB/4 and plywood boards on the wall (thickness > 18 mm) | + |
metal and steel | + |
plastics | + |
ATLAS ULTRA GEOFLEX technical data
Bulk density | 1.25 g/cm3 |
Mixing ratio (water/dry mix) | 0.27 ÷ 0.36 l / 1 kg 1.35 ÷ 1.8 l / 5 kg 6.08 ÷ 8.10 l / 22,5 kg 6.75 ÷ 9.00 l / 25 kg |
Min./max. bed depth | 2 mm / 15 mm |
dhesive preparation temperature, substrate and ambient temperature during work | from +5°C to +35°C |
Maturing time | 5 minutes |
Pot life* | approx. 4 hours |
Open time* | min. 30 minutes |
Adjustability time* | 20 minutes |
Walk on/grouting with cement grout* | after 12 hours |
Grouting with epoxy grout* | after 48 hours |
Full operation load – foot traffic* | after 3 days |
Full operation load – vehicle traffic* | after 14 days |
Full water load – pools/tanks* | after 14 days |
Floor heating (warm surface)* | after 14 days |
The time shown in the table is recommended for the application in the tempera- ture 20°C and humidity 55% (approx.).
ATLAS ULTRA GEOFLEX application
The substrate should be:
- stable – sufficiently sound, resistant to deformation, free from materials which would impair adhesion, stabilized.
- even – maximum adhesive thickness is 15 mm, in case of larger irregularities use, e.g. ATLAS ZW 330 mortar, screeds ATLAS SMS, SAM, POSTAR.
- clean – free from layers which can impair adhesion, especially dust, dirt, lime, oils, greases, wax, residues of oil and emulsion paints. The substrate coated with algae, fungi, etc. must be cleaned and protected with ATLAS MYKOS no 1 or ATLAS MYKOS PLUS agent.
- primed with: – ATLAS UNI-GRUNT, ATLAS UNI-GRUNT ULTRA or ATLAS UNI-GRUNT PLUS – substrates of excessive or heterogenous absorptiveness,
– ATLAS GRUNTO-PLAST – if the substrate absorptivity is low, or it is coated with layers limiting the adhesion.
– ATLAS ULTRAGRUNT – for critical substrates.
- damp-proofed – in case of tiling on surfaces exposed to water action:
– ATLAS WODER E – installation of cladding after 2 hours for damp-proofing and after 4 hours for waterproofing,
– ATLAS WODER W, ATLAS WODER S – installation of cladding after 24 h,
– ATLAS WODER DUO – installation of cladding after 12 h,
– ATLAS WODER DUO EXPRESS – installation of cladding after 3 h.
ATLAS ULTRA GEOFLEX Adhesive preparation
Pour the adhesive from the bag into a container with the suitable amount of water (see Technical Data for ratio) and mix, using a low speed mixer with a drill for mortars, until homogenous. The dispersed adhesive should be left to rest for 5 minutes and then remixed. So prepared adhesive should be used up within approx. 4 hours.
Adhesive application
The adhesive should be applied onto the surface with a steel trowel and then distributed evenly and shaped (possibly in one direction) with a notched trowel. It is advisable to rub a thin adhesive coat first and then apply the thicker coat and shape it with a notched trowel. It is recommended to lead a notched trowel in one direction. On walls, it’s recommended to shape the adhesive in vertical direction.
Placing the tiles
After the application, the adhesive retains its properties for approx. 30 minutes (in temperature approx. 23 °C and 55 % humidity). Within this time, the tile must be placed and pressed well (the contact surface between the adhesive and the tile should be uniform and as large as possible – min. 2/3 of tile surface). Remove the excess of the adhesive pressed into the joints immediately.
In case of floor tiles, tiling outdoors and large size tiles fixing, it is advisable to keep the full bonding surface (use the mixed method consisting in application of the adhesive on the substrate and tile bottom side, if needed). Keep the joint width appropriate for the tile size and operation conditions (check data in the sheets of ATLAS grouts).
Tile adjustment
The position of a tile can be adjusted with delicate moves along the bonding plane. It can be done within approximately 20 minutes since the tile is pressed (in temperature approx. 23 °C and 55 % humidity).
Grouting and cladding use
Foot traffic and grouting can start after:
– approx. 12 hours since the tiles fixing for ATLAS CERAMIC GROUT, ATLAS TIGHT GROUT, ATLAS DECORATIVE GROUT,
– approx. 48 hours since the tiles fixing for ATLAS EPOXY GROUT.
The mortar reaches the operational strength after 3 days (check the Technical Data). Expansion joints, joints along the wall corners, at sanitary equipment, etc. should be filled with sanitary silicone ATLAS ELASTIC SANITARY SILICONE or ATLAS SANITARY SILICONE SILTON S.
Exemplary Steps for installation of cladding
Step (following layer) | Product | Conditioning of the layer before execution of the next step* |
---|---|---|
Substrate levelling | levelling mortar ATLAS ZW 330 | approx. 5 h |
screed ATLAS POSTAR 80 screed ATLAS SMS 15 screed ATLAS SMS 30 | approx. 1 day | |
screed ATLAS POSTAR 20 | approx. 2 days | |
screed ATLAS POSTAR 10 screed ATLAS SAM 100 | approx. 14 days | |
screed ATLAS POSTAR 100 screed ATLAS POSTAR 40 screed ATLAS SAM 200 screed ATLAS SAM 500 | approx. 21 days | |
Damp-proofing** | ATLAS WODER E ATLAS WODER S ATLAS WODER W ATLAS WODER DUO ATLAS WODER DUO EXPRESS | approx. 2 h approx. 24 h approx. 24 h approx. 12 h approx. 3 h |
Installation of tiles | ATLAS ULTRA GEOFLEX | approx. 12 h – wall |
Grouting of tiles | grouting mortar ATLAS | - |
There are no reviews yet.