Mapei Planitop Fast 330 extended information
- Where to use: internal walls and floors for ceramic and natural stone coatings.
- Workability time: approximately 20 minutes.
- Thickness applied: from 3 to 30 mm.
- Waiting time before laying ceramic and natural stone: 4 hours, varies according to the surrounding temperature.
- Application: smooth trowel.
- EMICODE: EC1 – very low emission.
- Colour: grey.
- Storage: 12 months.
- Consumption: 1.45 kg/m² per mm of thickness.
- Packaging: 25 kg vacuum-packed polyethylene bags.
Mapei Planitop Fast 330 Where To Use
To smooth irregular internal and external substrates to quickly make them suitable for laying ceramic and stone or for waterproofing with liquid membrane or flexible cementitious systems. Applied at a thickness from 3 to 30 mm
Some application examples
- Levelling reinforced concrete surfaces in swimming pools to make them ready to receive (after just 24 hours at +20°C) Mapelastic and Mapelastic Smart waterproofing systems or, after 4 hours at +20°C, for directly laying all types of ceramics and mosaics.
- Smoothing and levelling clean internal and external substrates made from products normally used in the building industry, such as floor slabs and screeds made using cement or special binders (such as Mapei Topcem, Topcem Pronto, Mapei Mapecem and Mapecem Pronto) and old ceramic and stone floors in order to quickly prepare them for laying (after just 4 hours at +20°C), ceramic and stone materials which are not sensitive to damp, or for applying waterproofing systems such as Mapelastic, Mapelastic Smart and Mapegum WPS (after just 24 hours at +20°C).
- Repairing or forming slopes on terraces and balconies
Mapei Planitop Fast 330 Technical Characteristics
Planitop Fast 330 is a grey-coloured one-component cementitious mortar with very low emission of volatile organic compounds (EMICODE EC1) made using special cementitious binders, selected aggregates materials, synthetic resins and special additives according to a formula developed in MAPEI’s Research & Development laboratories.
When mixed with water, it forms a blend with good workability which may be applied on vertical surfaces by trowel, characterised by its high bonding strength to all substrates normally used in the building industry.
Mapei Planitop Fast 330 hardens quickly even when applied in thick layers without shrinking or cracking, and forms a strong layer suitable for laying ceramic, glass mosaic and stone finishes.
Mapei Planitop Fast 330 meets the main requirement of EN 1504-9 (“Products and systems for protecting and repairing concrete structures: definitions, requirements, quality control and conformity assessment. General principles for the use of products and systems”) and the minimum requirements of EN 1504-2 coating (C) according to principles MC and IR (“Concrete surface protection systems”) and is classified as GP (“General purpose mortar for internal/external render”), category CS IV according to EN 998-1.
Recommendations
Do not mix Mapei Planitop Fast 330 with cement or other products and never add water to the mix once it has started to set.
Protect the surface to avoid the water evaporating too quickly in hot and/or windy weather.
After applying Planitop Fast 330, protect the surface from water for at least 4 hours at +20°C and 24 hours at +5°C, and in all cases, until it has hardened.
Apply at a temperature between +5°C and +35°C.
Do not leave bags of Planitop Fast 330 exposed to the sun for long periods before use.
Do not use this product on flexible, deformable substrates such as wood and wood conglomerates, metal, rubber, PVC and linoleum.
Mapei Planitop Fast 330 Application Procedure
Preparation of the substrate
The substrate must be cured, compact and free of dust, loose parts, oil, grease and traces of paint and
adhesive.
Surfaces exposed to direct sunlight or winds must be wetted beforehand. Particularly absorbent substrates. (such as bricks, lightweight concrete blocks, etc.) must be wetted before applying Mapei Planitop Fast 330, especially when applied in thin layers.
Gypsum substrates and anhydrite screeds must be perfectly dry, hard enough for the final intended use and free of dust. They must also be treated with Mapei Primer G or Mapei Eco Prim T Plus.
Concrete surfaces must be well cured, clean, free of dust and cement laitance and, where necessary, treated with Eco Prim Grip Plus.
Smooth substrates and substrates with low or no absorbency, such as ceramics, terrazzo or concrete with a finish of smoothing and levelling compound, must be cleaned, mechanically abraded and treated with Eco Prim Grip Plus.
Preparation of the mix
Pour a 25 kg bag of Planitop Fast 330 into a container with 4.5-5 litres of clean water while mixing (18-20 parts of water per 100 parts in weight of Mapei Planitop Fast 330) and mix with a low-speed mixer to form a smooth, lumpfree blend. The blend remains workable for approximately 20 minutes (at +20°C).
Application of the mix
On walls:
Apply a feather edge layer of Mapei Planitop Fast 330 on the substrate to form a perfectly buttered layer and then immediately apply the product at the thickness required to level and even out the substrate in a single layer (up to a maximum of 3 cm).
If thick layers are required, Planitop Fast 330 may be applied with a smooth trowel by pressing it down well onto the substrate and then levelling off with a metal straight edge (final finishing with a sponge float).
On floors:
Apply the mix with a long metal pallet knife or trowel.
Laying of coatings and waterproofing
Waterproofing layers of Mapelastic, Mapelastic Smart and Mapegum WPS may be applied after approximately 24 hours at +20°C. Ceramic tiles, stone (not sensitive to moisture) and all types of mosaic may be laid after approximately 4 hours at +20°C and after 24 hours at +5°C.
Curing
Protect the surface against water evaporating too quickly during hot and/or windy weather and avoid the mortar coming into contact with water for the first 4 hours at +20°C and for the first 24 hours at +5°C.
Mapei Planitop Fast 330 technical data
Mapei Planitop Fast 330: Quick setting cementitious mortar for internal and external use applied at a thickness from 3-30mm to smooth out irregularities in floors and walls, in compliance with the requirements defined by EN 1504-2 and EN 998-1
Product identity
Consistency | Powder |
Colour | grey |
Maximum size of aggregate (mm): | 1 |
Bulk density (kg/m³): | 1,300 |
Dry solids content (%): | 100 |
EMICODE | EC1 – very low emission |
Application data
Colour of mix: | grey |
Mixing ratio: | 100 parts of Planitop Fast 330 with 18-20 parts water (4.5-5 litres of water per 25kg bag) |
Density of the mix according to EN 1015-6 (kg/m³): | 1850 |
Maximum applied thickness (mm): | 30 |
Application temperature range: | From +5°C to +35°C |
Minimum waiting time before laying ceramic coating: | 4 hours at +20°C 24 hours at +5°C |
Mapei Planitop Fast 330 final performances
Performance characteristic | Test method | Requirements EN 1504-2 MC and IR | Requirements EN 998-1 GP – CS IV | Product performance |
---|---|---|---|---|
Compressive strength (MPa): | EN 12190 | not required | not required | ≥ 20 (after 28 days) |
Bond strength on concrete (substrate in MC 0.40) according to EN 1766 (MPa): | EN 1542 | for rigid systems: without traffic ≥ 1.0 With traffic ≥ 2.0 | not required | ≥ 2.0 (after 28 days) |
Impermeability expressed as coefficient of permeability to free water (kg/m²·h0.5): | EN 1062-3 | W < 0.1 | not required | W < 0.1 Class III (low permeability to water) according to EN 1062-1 |
Permeability to water vapour – equivalent air thickness SD (m) | EN ISO 7783- 1 | Class I SD < 5 m Class II 5 m ≤ SD ≤ 50 m Class I SD > 50 m | not required | Class I (SD < 5 m) |
Compressive strength 28 days (MPa): | EN 1015-11 | Not required | ≥ 6 category CS IV | ≥ 20 category CS IV |
Adhesion to the substrate (brickwork) (MPa): | EN 1015-12 | not required | declared value and failure pattern (FP) | ≥ 1.5 failure pattern (FP) = B |
Capillary absorption [kg/(m²·min )]: | EN 1015-18 | not required | W (not specified) W (≤ 0.40) W (≤ 0.20) | Category WC2 |
Thermal conductivity (λ10,dry) (W/m·K): | EN 1745 | not required | chart value | 0.67 |
Reaction to fire: | EN 13501-1 | Euroclass | Euroclass | A1/A1FL |
There are no reviews yet.